Technical Parameters of ABB SPAA 341 C2 REV.A Feeder Protection + Test Switch Relay
The ABB SPAA 341 C2 REV.A is a comprehensive feeder protection relay designed for advanced electrical system monitoring, protection, and testing in medium-voltage distribution networks. Below are its key technical specifications:
1. Protection Functions
- Overcurrent Protection:
- Phase and ground fault detection with adjustable time-current characteristics (IDMTL, definite-time, instantaneous).
- Supports thermal overload protection for cables and transformers.
- Voltage Monitoring:
- Overvoltage, undervoltage, and phase sequence/loss protection.
- Voltage unbalance detection for three-phase systems.
- Earth Fault Protection:
- Sensitive ground fault detection with adjustable thresholds and time delays.
- Breaker Failure Protection:
- Backup protection for circuit breakers in case of malfunction.
- Test Switch Integration:
- Built-in test switch for manual/automatic relay testing without disconnecting the secondary wiring.
2. Measurement & Metering
- Current Measurement:
- Three-phase current (RMS) measurement with 0.5% accuracy.
- Supports CT secondary ratings from 1 A to 5 A.
- Voltage Measurement:
- Three-phase voltage (RMS) measurement with 0.5% accuracy.
- Supports VT secondary ratings from 100 V to 230 V (line-to-neutral).
- Power & Energy Metering:
- Active/reactive power, power factor, and energy consumption (kWh, kVArh) monitoring.
3. Communication & I/O
- Communication Protocols:
- Modbus RTU/TCP, IEC 60870-5-103, DNP3 (optional).
- Ethernet/RS485 ports for SCADA integration.
- Digital Inputs/Outputs:
- 4 programmable digital inputs (for block signals, remote reset, etc.).
- 3 relay outputs (for tripping, alarms, status indication).
- HMI & Display:
- Backlit LCD display for real-time measurements, event logs, and relay settings.
- LED indicators for relay status, alarms, and communication activity.
4. Settings & Configuration
- Flexible Configuration:
- Front-panel keypad or software-based configuration via EnerVista™ ABB software.
- Supports multiple protection curves (ANSI, IEC, or user-defined).
- Event Recording:
- Stores up to 256 events with time-stamping (1 ms resolution).
- Oscillographic recording of fault waveforms (post-mortem analysis).
5. Mechanical & Environmental Specifications
- Form Factor:
- Panel-mounted design (DIN rail or substation enclosure compatible).
- Power Supply:
- AC/DC: 80–265 V (50/60 Hz), with ±15% voltage tolerance.
- Power consumption: < 5 W (typical).
- Operating Temperature:
- -25°C to +70°C (extended range available).
- Protection Class:
- IP40 (front panel), IP20 (rear terminals).
- EMC Compliance:
- IEC 61000-6-2 (immunity), IEC 61000-6-4 (emissions).
6. Testing & Maintenance
- Test Switch Features:
- Manual/automatic test mode for relay functionality verification.
- Simulates overcurrent, undervoltage, and ground fault conditions.
- Self-Diagnostics:
- Continuous monitoring of relay health (CT/VT supervision, memory errors, etc.).
7. Certifications & Standards
- Compliance:
- IEC 60255, UL 508, CSA C22.2 No. 14, and other relevant international standards.
- Safety Certifications:
- CE, UL, and CCC (China Compulsory Certificate).
8. Applications
- Industrial Feeders:
- Protection of motors, transformers, and cables in manufacturing plants.
- Utility Distribution:
- Overhead line and underground cable protection in distribution networks.
- Renewable Energy:
- Feeder protection in solar/wind farms and battery storage systems.
The ABB SPAA 341 C2 REV.A combines robust protection, accurate metering, and advanced testing capabilities in a compact, user-friendly package. Its modular design and compliance with global standards make it suitable for a wide range of industrial and utility applications.
For detailed configuration guides or firmware updates, refer to ABB’s EnerVista™ software documentation or contact authorized ABB distributors.

