ABB 1MRK002311-AAR02 Interface Module For Protection Relay
The ABB 1MRK002311-AAR02 is a specialized communication and interface module designed for the RELION 670 and 650 series protection and control relays. It facilitates high-speed data exchange and provides the necessary physical interface for various communication protocols within a substation automation system.
Technical Specifications & Parameters
Product Technical Description
The 1MRK002311-AAR02 acts as a bridge between the primary protection logic and the station bus. Key technical functions include:
Sampled Values Integration: Supports the transmission and reception of digitalized analog values according to the IEC 61850-9-2 standard, enabling "Digital Substation" architectures.
Galvanic Isolation: Provides superior electromagnetic interference (EMI) immunity by using optical fibers, which is critical in high-voltage environments.
Time Synchronization: Supports high-precision time stamping (IEEE 1588 / PTP) to ensure that event logs and protection trips across different relays are perfectly synchronized.
Redundancy Support: Compatible with Parallel Redundancy Protocol (PRP) and High-availability Seamless Redundancy (HSR) to ensure zero-loss communication during network failures.
Country of Origin
The 1MRK002311-AAR02 is engineered and manufactured in Sweden.
Common Questions & Answers (Q&A)
Q: Can this module be used for line differential communication?A: While it handles station bus communication, specific LDCM (Line Differential Communication Modules) are usually required for direct relay-to-relay protection signaling over long distances. This module is primarily for station-level integration.
Q: Is it possible to replace the SFP transceiver on this board?A: Yes, the module is designed to accept different SFP (Small Form-factor Pluggable) transceivers to match the specific fiber distance and connector type required for your site.
Q: Does it require manual addressing?A: No, the IP addressing and technical parameters are configured via the PCM600 (Protection and Control IED Manager) software.
Q: What happens if the optical link is lost?A: The relay will trigger a "Communication Fail" alarm. If configured for PRP/HSR, the secondary link will take over instantly without interrupting protection functions.
同类文章排行
- 5SHX1960L0006 3BHB016120R0002
- ABB厦门工业中心“碳中和”园区示范基地落成
- 3500/22M 288055-01 表面检测系统分类性能的
- UAD149A0001 3BHE014135R0001 破解
- 怎么联系业务?
- 协作机器人市场能否在后疫情时代迎来二次增长?
- 5SHX1960L0006 3BHB016120R0002
- 3500/33-01-00 全集成线扫描接触式图像传感器
- 辉瑞6年的工业数字化转型历程与成果
- 5SHY4045L0003 3BHB021400 克服制造
最新资讯文章
- ABB 3BHE037649R0101 | PDD500A1
- ABB 07AC91 | GJR5252300R0101 I
- 500SCM01 1MRE450004R1 | ABB Co
- G3FE HENF452697R1 | ABB DCS In
- ABB UAD149A0001 | 3BHE014135R0
- ABB PPD113B01-10-150000 | AC 8
- 500MBA02 1MRB150003R0003 | ABB
- DYPS154C 61430001-YP | ABB Ind
- ABB 216VC62A | HESG324442R112/
- ABB PFXA401S | 3BSE024388R2 In