ABB REF601 | CE446BB1NH Feeder Protection and Control Relay
The REF601 (Part Code: CE446BB1NH) is a dedicated feeder protection and control relay from the ABB Relion® 605 series. It is designed for protection, control, measurement, and supervision of utility and industrial power distribution systems. This compact numerical relay is primarily used for short-circuit and overcurrent protection in medium-voltage networks, offering a high level of reliability and a user-friendly interface for local operation.
Product Datasheet & Parameters
Product Technical Description
The REF601 CE446BB1NH serves as a vital safeguard for electrical distribution assets. It integrates multiple protection functions into a single hardware unit, reducing the need for multiple discrete components.
Key Functional Characteristics:
Overcurrent Protection: Features three-stage non-directional overcurrent protection (low-set, high-set, and instantaneous).
Earth-Fault Protection: Provides sensitive earth-fault detection to prevent equipment damage during insulation failure.
Measurement Capabilities: Real-time monitoring of phase currents and earth current, accessible via the front HMI (Human Machine Interface).
Fault Recording: Stores trip data and fault current values for the last five events, assisting in rapid post-fault analysis.
Self-Supervision: Continuous internal monitoring of hardware and software integrity; an internal watchdog triggers an alarm if a system fault is detected.
Country of Origin
Original Country: India (IN) / Estonia (EE)
Manufacturer: ABB Distribution Solutions
Common Questions & Answers (Q&A)
Q: What does the "CE446BB1NH" code specify?A: This specific hardware configuration code defines the auxiliary power supply range, the number of binary inputs/outputs, the communication protocol (Modbus), and the physical casing type.
Q: Can this relay be used for motor protection?A: While the REF601 is optimized for feeders, it can provide basic overcurrent and earth-fault protection for motors. However, for specialized motor protection (like thermal overload or locked rotor), the REM601 variant is typically recommended.
Q: Is the communication port isolated?A: Yes, the RS-485 communication port used for Modbus RTU is galvanically isolated to ensure data integrity and protect the relay from surges on the communication bus.
Q: How do I reset a trip condition on the REF601?A: Trips can be reset locally using the "RESET" button on the front panel HMI once the fault has been cleared, or remotely via the binary inputs or communication link.
同类文章排行
- 5SHX1960L0006 3BHB016120R0002
- ABB厦门工业中心“碳中和”园区示范基地落成
- 3500/22M 288055-01 表面检测系统分类性能的
- UAD149A0001 3BHE014135R0001 破解
- 怎么联系业务?
- 协作机器人市场能否在后疫情时代迎来二次增长?
- 5SHX1960L0006 3BHB016120R0002
- 3500/33-01-00 全集成线扫描接触式图像传感器
- 辉瑞6年的工业数字化转型历程与成果
- 5SHY4045L0003 3BHB021400 克服制造
最新资讯文章
- ABB 3BHE037649R0101 | PDD500A1
- ABB 07AC91 | GJR5252300R0101 I
- 500SCM01 1MRE450004R1 | ABB Co
- G3FE HENF452697R1 | ABB DCS In
- ABB UAD149A0001 | 3BHE014135R0
- ABB PPD113B01-10-150000 | AC 8
- 500MBA02 1MRB150003R0003 | ABB
- DYPS154C 61430001-YP | ABB Ind
- ABB 216VC62A | HESG324442R112/
- ABB PFXA401S | 3BSE024388R2 In